Voltage Probe Manual and Data

North Star Research Corporation

 

Standard Voltage Probe Data

High Voltage Probes Up to 400 kV

 

High Voltage Probes

High voltage measurements have a variety of different requirements, and our PVM series and VD series probes are designed for most of these requirements. The PVM probes are designed for wide bandwidth and ease of portability where a variety of measurements must be made. The VD series probes are designed for use at higher voltage ranges, and where physical stability is required.

Specialty Probes PVM series probes with PVM-5 on top and PVM-10 on the bottom

The design of the probes is unique. The probe comes fully adjusted without any requirement to further adjust the probe in the field. Stray capacitances internal to the probe are factory calibrated. Stray capacitances due to proximity effects are minimied by the unique conductor placement.

Low temperature and voltage coefficient resistors and capacitors are used throughout the probe to provide maximum measurement accuracy. The probe has a rugged nylon housing, and it is filled with dielectric oil for maximum high voltage stability.

Our PVM Series probes our available with either 1000:1 or 2000:1 calibration factors at the time of order.

Voltage Probe Specifications

PVM Series Portable High Voltage Probes to 60 kV DC

PVM series high voltage probes are designed for general use, and for exceptional high frequency response. The probes have applications ranging from automotive ignition to excimer laser system measurement to EMI measurement. They are factory calibrated, and they do not require adjustment. In general the probes are for use with 1 Megohm oscilloscopes, but we also offer an optional switch which can compensate for various measurement instruments such as 10 Megohm meters as well. These units are intended for a wide range of applications where portability and ease of use are essential.

 

Model Number

PVM-1

PVM-2

PVM-3

PVM-4

PVM-5

PVM-6

PVM-11 (PVM-10)

PVM-12

Max DC/Pulsed V (kV)

40/60

40/60

40/60

40/60

60/100

60/100

10/12

25/30

Max Frequency (Mh.)

80

80

40

110

80

80

50

80

Cable Impedance (ohms)

50

50

50

93

50

50

50

50

DC - 2 H.accuracy

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

2 H. - 200 H. accuracy

<1 %

<1. %

<2. %

<1. %

<1 %

<1 %

<1.5 %

<1.5 %

200 H. - 5 Mh. accuracy

<1.5%

<1.5%

<3%

<1.5%

<1.5%

<1.5%

<2.%

<2.%

> 5 Mh. Accuracy

<3%

<3%

<4%

<5%

<3%

<4%

<4%

<4%

Input R/C (Megohm/pf)

400/13

400/13

400/10

400/10

400/12

400/12

100(50)/15

300/7

Cable Length (ft./m)

15/4.5

30/9

100/30

15/4.5

15/4.5

30/9

15/4.5

15/4.5

Standard Divider Ratio

1000:1

1000:1

10,000:1

1000:1

1000:1

1000:1

1000:1 (100:1)

1000:1

Length (inches/cm.)

19/47

19/47

19/47

19/47

19/47

19/47

7/18

9/23

*美NORTH STAR 高壓探頭

Add -2 to any PVM-1 - PVM-6 or PVM-12 part number for 2000:1 ratio

VD Series High Voltage Probes 60 to 300 kV DC

Specialty Probes

VD series high voltage probes are floor standing high voltage probes which are designed for rugged day in - day out use. They are used in a wide range of applications ranging from evision tube manufacturing to radar to advanced particle accelerator applications. Resistors with an extremely low voltage coefficient of resistance are used, and all capacitors are temperature, frequency, and voltage stabilied for the best possible performance. The probes all have field defining toroids as a standard item in order to minimie the proximity effect (stray *美NORTH STAR 高壓探頭capacitance) and maximie the reproducibility of the measurement. The high and low frequency calibrations are carefully matched before shipment. Very high frequency cable effects are also carefully compensated so accurate measurements can be made even when the cable length exceeds the pulse duration. No adjustments are necessary once the probes have been factory calibrated.

Model Number

VD-60

VD-100

VD-150

VD-200

VD-300

VD-400

Max DC/Pulsed V (kV)

60/120

100/180

150/240

200/300

300/420

400/550

Max Frequency (Mh.)

20

20

20

16

12

8

Cable Length (ft.)

30

30

30

30

30

30

DC accuracy

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

<0.1%

10 H. - 1 Mh. Accuracy

1 %

1 %

1 %

2 %

2.5 %

3 %

>1 Mh Accuracy

3 %

3 %

3 %

3 %

4 %

4 %

Resistance (Megohms)

800

1600

2000

2800

4500

7000

Height (inches/cm.)

20/50

24/60

30/75

40/99

54/135

72/180

Diameter (in/cm.)

11/28

11/28

12/29

16/40

24/61

24/61

Capacitance (approx. pf)

27

25

27

24

20

16

Base Diameter(in/cm.)

10/25

10/25

12/30

20/50

30/76*

30/76

Standard Divider Ratio

10,000:1

10,000:1

10,000:1

10,000:1

10,000:1

10,000:1

 

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗(yàn)證碼:

    請(qǐng)輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7
北京志鴻恒拓科技有限公司

北京志鴻恒拓科技有限公司

地址:北京市朝陽(yáng)區(qū)建國(guó)路88號(hào)soho現(xiàn)代城

© 2024 版權(quán)所有:北京志鴻恒拓科技有限公司  備案號(hào):京ICP備16029562號(hào)-5  總訪問量:566585  sitemap.xml  技術(shù)支持:化工儀器網(wǎng)  管理登陸

51精产国品一二三产区区别| 色噜噜狠狠一区二区三区果冻| 国产精品天天看天天做夜夜爽| 日韩精品无码一本二本三本色 | 欧美成人一区二区三区| 久久精品国产99国产精偷| 丰满中国少妇和黑人玩| 最近韩国免费高清观看视频| 亚洲国产AV无码精品无广告| 校花张开腿疯狂娇吟k视频| 99精品无码一区二区毛片免费| 国产成人AAAAA级毛片| 女子全员妊娠计划| 中国videosex高潮对白| 国产乱来乱子视频| 亚洲色欲久久久久综合网| 我和黑帮老大的365天| 女人与公拘交酡过程| 免费观看丰满少妇做受| 久久久久久久女国产乱让韩| 激情97综合亚洲色婷婷五| 翁与小莹浴室欢爱51章| 张柏芝殖器十二图片| 久久99亚洲精品久久久久| 老人玩小处雌女视频| 精品国产乱码久久久久久毛片| 99精品久久精品一区二区| 中国人妻被两个老外三P| 97精品人人a片免费看| heyzo无码中文字幕人妻 | 裙底下的男友1v1校园高h| 国产色情一区二区视频| 亚洲AV无码精品国产天堂-百度| 国产AV无码专区亚洲AV麻豆| 人与牲动交XXXXBBBB| 亚洲AV无码AV日韩AV网站| 男男调教后菊撑开扩张a片| 又白又嫩毛又多15p| 日日噜噜夜夜狠狠久久人人| 总裁攻紧致h粗大学生受小说| 娜娜的yin荡生涯h全文|